EZ-Path Series 33NEZ Smoke & Acoustical Pathway

EZ-Path Series 33NEZ Smoke & Acoustical Pathway
EZ-Path Series 33NEZ Smoke & Acoustical Pathway
EZ-Path Series 33NEZ Smoke & Acoustical Pathway
EZ-Path Series 33NEZ Smoke & Acoustical Pathway

EZ-Path Series 33NEZ Smoke & Acoustical Pathway

Designed for easy installation in non-rated floor, ceilings, and walls, EZ Path Series 33NEZ Smoke & Acoustical Pathway provides exceptional cable capacity with tested and approved cable capacities ranging from 0 up to 100% visual fill. A single unit installed in a wall exceeds the cable carrying capacity of a 4" (102 mm) sleeve utilizing typical putty firestop systems (35% cable loading).

Test Standards ASTM E90
Third Party Approvals

Features

  • Cable management by use, type and vendor
  • Zero maintenance - easy moves, adds and changes
  • Excellent acoustical performance; low smoke leakage ratings
  • Easy to install - can be installed horizontally and vertically
  • Clean, engineered appearance
  • Pathways can be ganged for additional capacity
  • Pathway adjusts to accommodate wall, floor and ceiling thicknesses between 4 in (102 mm) and 8 in (203 mm)
Applications
Cables
Properties
Finished Product
Light Weight
Low VOC
No Expiration
Paintable
Re-Enterable
STC Rating
Zero Maintenance
Smoke Barrier

Specifications

Property Value
Shell Composition Non-Halogenated, V-0 High Impact ABS/PC Thermoplastic
Seal & Curtain Flame Retardant, Low-Smoke Silicone Rubber
Cable Loading Area 6.7 sq in (43.2 sq cm)
Allowable Cable Fill 0% to 100%
In Service Temperature -30°F (-34°C) - 130°F (54°C)
Storage Temperature Less than 130°F (54°C)
L Rating (CFM/Device) (0% Visual Fill) Less than 1*
L Rating (CFM/Device) (100% Visual Fill) Less than 2.5*
Plenum Tested to UL2043
Sound Transmission Classification (STC) 61 (Relates to Specific Construction) (ASTM E 90-09)
Notes *L Ratings Tested According to Air Leakage Test Procedure As Outlined in UL1479 without a Fire Test. For use in non-fire-rated construction only.

Ordering Information

Catalog Number UPC Number Description (UOM) Qty. Case Qty. Weight (Each) Image
NEZ33 730573111581 EZ-Path Smoke and Acoustical Pathway (Device Only) 1 4 lbs EZ-Path Smoke and Acoustical Pathway (Device Only)
NEZ33CK2 730573111680 EZ-Path Smoke and Acoustical Pathway with Ceiling Kit 1 1 lbs EZ-Path Smoke and Acoustical Pathway with Ceiling Kit
NEZ33R 730573111659 EZ-Path Smoke and Acoustical Pathway Retrofit Kit 1 1 lbs EZ-Path Smoke and Acoustical Pathway Retrofit Kit
NEZ33-W 730573111666 EZ Path Smoke and Acoustical Pathway - White 1 4 lbs EZ Path Smoke and Acoustical Pathway - White
NEZDP233 730573111598 EZ-Path Smoke and Acoustical Pathway ( 2 Gang Kit) 1 1 lbs EZ-Path Smoke and Acoustical Pathway ( 2 Gang Kit)
NEZDP433 730573111604 EZ-Path Smoke and Acoustical Pathway (4 Gang Kit) 1 1 lbs EZ-Path Smoke and Acoustical Pathway (4 Gang Kit)
NEZP233 730573111611 EZ-Path Smoke and Acoustical Pathway 2 Gang Plate Kit 1 1 lbs EZ-Path Smoke and Acoustical Pathway 2 Gang Plate Kit
NEZP433 730573111628 EZ-Path Smoke and Acoustical Pathway 4 Gang Plate Kit 1 1 lbs EZ-Path Smoke and Acoustical Pathway 4 Gang Plate Kit
EZ-Path Series 33NEZ Smoke & Acoustical Pathway
Designed for easy installation in non-rated floors and walls, these pathways have been tested and approved cable capacities ranging from 0 to 100% visual fill. In these installations, the device does not require mechanical attachment to either the wall or the wall framing and may be installed after the wallboard has been installed. With it’s split body design, the device can be easily disassembled and installed around previously installed cables in existing construction.